Basic Raised Floor Mount Fan

InfraCool

InfraCool Basic Raised Floor Mount Fan F-66.4 help deliver strong cool air from underfloor via the contained aisle to high density server racks to eliminate internal hot spots. Maximizes CRAC (Computer Room Air Conditioning) efficiency and saves energy costs.

InfraCool Raised Floor Mount Fan Unit (F-66.4 / WF-66.4) Animation - Air From Bottom
Bottom
Cool Air In
InfraCool Raised Floor Mount Fan Unit (F-66.4B / WF-66.4B) Animation - Air From Top
Top
Cool Air In

Filter products
Form Factor
Fan Type
Max. Total Fan Capacity
Fan Features
Cascade / Expansion

High quality, low-cost, Raised Floor Mount Fans

InfraCool Basic Raised Floor Mount Fan F-66.4 help deliver strong cool air from underfloor via the contained aisle to high density server racks to eliminate internal hot spots. Maximizes CRAC (Computer Room Air Conditioning) efficiency and saves energy costs.

Play Video

InfraCool Raised Floor Mount Fan Unit (F-66.4 / WF-66.4) Animation - Air From Bottom
Bottom
Cool Air In
InfraCool Raised Floor Mount Fan Unit (F-66.4B / WF-66.4B) Animation - Air From Top
Top
Cool Air In

Key Benefits

  • Basic - Quad EC ( Electronically  Communicated ) Fans

    Quad EC ( Electronically Communicated ) Fans

    InfraCool® F-66.4 consists of four high performance and quality EC fans. It provides unit CFM up to 2,100 and unit MTBF up to 50,000 hours.
  • Basic - Maximize CRAC Efficiency & Minimize Rack Hot Spots

    Maximize CRAC Efficiency & Minimize Rack Hot Spots

    InfraCool® F-66.4 delivers strong cool air from underfloor via the contained aisle to the high density server racks to eliminate inside hot spots. Eventually, F-66.4 not only maximizes CRAC efficiency, but also saves energy cost.
  • Basic - Individual Fan On / Off

    Individual Fan On / Off

    Each EC fan is equipped with an individual on / off switch. It provides flexibility for users while the aisle environment or rack cooling requirement changes.
  • Basic - Unit / Fan Speed Levels

    Unit / Fan Speed Levels

    Each EC fan is provided with 3 speed levels. User can adjust the speed level according to aisle environment and requirements. Energy expenses for the cooling become more cost-effective as lower speed level costs much less.
  • Basic - Overall Temperature Monitoring

    Overall Temperature Monitoring

    By two temp. sensors and LED display, it is easy to monitor the temperature status in rack level, aisle level and even air duct underfloor level. Eventually, user can be aware of overall temperature environment.

Model Overview

Raised Floor Basic Fan Unit series offers models with air intake from the bottom or top of the rack.

Depending on the users application, they can implement cold-aisle containment maximizing cooling, energy efficiency, and protecting server equipment.

Comparison Table

Control & Monitoring

Control Panel

F-66.4 is integrated with a control panel for easy management. Users can switch on / off for individual EC fans. Apart from individual EC Fan status and CFM figures, it also provides monitoring of temperature detected by the two sensors.

InfraCool Basic Raised Floor Fan Control Panel

Temperature Sensor

With two included temperature sensors, it is easy to monitor the temperature status in rack level, aisle level and even air duct underfloor level. Eventually, user can be aware of overall temperature environment.

Austin Hughes Basic Temperature Sensor

Bundled Temp. Sensor x2

  • Plug & Play
  • 2M Wire

Management and Setup

Basic Raised Floor Fan Package Contents

  1. Fan Unit
  2. Temperature sensor with cable x 2
  3. Support bracket, left & right side
  4. Bracket fi xing plate x 4
  5. M8 screw & nut x 8 ( for fi xing plate )
  6. M5 screw x 4

Before Installation

  • Make sure the fan unit is installed under the 600 x 600mm raised floor & located in front of the server rack.
  • The fan unit contains moving parts which may cause serious injury. Don’t apply power until the installation is complete.
  • The fan unit must be installed by a qualified electrician and comply with local and national regulations.
  • Use the provided input power cord to connect the unit. The power voltage must be rated 208V or 230V.
  • Never disassemble the unit. It contains potentially hazardous voltages.

Accessories

Austin Hughes Basic Temperature Sensor

Temperature Sensor (2x included)

  • Plug & play
  • 2M wire

High-quality Build with Certifications for any application

Product Warranty

2 years standard warranty on all purchases. Expandable up to 5 years.

Certifications

CE, FCC, REACH, RoHS3, LDV Certified, and TAA Compliant.

Built-to-last

MTBF (Mean-Time-Between-Failure) of 50,000 Hours.

Global Support

Extensive authorized distributions network around the globe.

Customer Commitment

Enhance customer competitiveness through our world class quality solutions and services.

Go Green Business

BSI ISO9001 / ISO14001 accredited ensuring maximum operating efficiency.

CE Certified
FCC Certified
REACH Compliant
RoHS3 Compliant
Click outside to hide the comparison bar
Compare
Scroll to Top