Austin Hughes designed the cost-effectiveness InfraPower Metered ATS series. It is perfect for the users who are
looking for a reliable but affordable basic ATS with local meter.
The ATS are equipment with a digital meter for real time local current monitoring. The blue LED
display is easy-to-read and allows rapid monitoring to the aggregate load on the PDU circuit.
Metered Automatic Transfer Switch (ATS)
Austin Hughes designed the cost-effectiveness InfraPower Metered ATS series. It is perfect for the users who are
looking for a reliable but affordable basic ATS with local meter.
The ATS are equipment with a digital meter for real time local current monitoring. The blue LED
display is easy-to-read and allows rapid monitoring to the aggregate load on the PDU circuit.
Key Benefits
-
Sometimes manual power input switching function is essential, especially during the maintenance service in data center. InfraPower® ATS is bundled with an Input Preference Switch. It allows user to set the power source preference to supply the output.
-
Most data centers provide power source redundancy in order to ensure that critical devices have no power downtime issue. Some rackmount IT devices, however, are not designed with power redundancy. For single-corded devices, InfraPower® ATS is a perfect fit to provide power fallback. It includes dual power inlets, for connection to both a primary power source and a redundant, secondary power source.
-
InfraPower® ATS offers a simple but reliable solution for automatically sensing power loss and seamlessly switching to a secondary power source. The power source transfer time is seamless to the connected equipment, making sure that the switching occurs safely between the two input power sources. After switching to a backup power source, it can also switch power back to the primary input after power has been restored.
-
MD meter provides a local 3-digit RMS current measurement with accuracy ± ( 3% of the reading + 5 last digits ) RMS. It helps avoid current overload in a high density equipment environment. A Blue LED indicator allows easy local reading of current, especially when there is no lighting installed inside the rack as is typical in a data center environment.
-
The leading edge ATS solution provides the widest range of configurations with shortest lead-times in the market : It offers 110V / 208V / 230V models with input range from 10A to 32A, outlet number from 1 to 24 and variety of outlet types ( e.g. NEMA, C13, C19, UK, Schuko, French, etc ). Custom configurations are available upon request.
Hardware

- 3-digit LED meter display for current only
- Power LED – primary input
- Input Preference Switch
- Power LED – secondary input
- Hydraulic MCB

Redundant Power
Automatic Transfer Switches (ATS) provide fail-safe power redundancy. A rack ATS has dual input power cords supplying power to the connected load. If the primary power source becomes unavailable, the rack ATS will seamlessly source power from the secondary source without interrupting critical loads.

Accessories

Miniature Circuit Breaker (MCB)
MCB
- Hydraulic magnetic MCB
- Overload switch
- Designed to prevent accidental on / off operation
- Safety Regulatory : UL / cUL / TUV / CE
- Free bundled by all ATS models

Cord Retention Tray
Free
- Located at the side of outlets
- Facilitate cabling
- Simply use the cable ties to fasten each power cord to the cord retention tray
- Free bundled by all ATS models